Product Details:
Usage/Application | Construction |
Model Name/Number | Sprinter 50 |
Level Accuracy | 2 mm |
Warranty | 1 year |
Environmental Conditions | IP55 |
Brand | Leica |
Range | 2 to 100 m (electronic) |
Telescope | Magnifi cation (optical) 24 x |
Technical Data | Sprinter 50 |
Height accuracies Electronic measurement Optical measurement |
Standard deviation height measurement per 1 km double run (ISO 17123-2) |
2.0 mm | |
With standard aluminum E-scale/Numeral staff: 2.5 mm | |
Single staff reading | Standard Deviation: 0.6 mm (electronic) and 1.2 mm (optical) at 30 m |
Distance accuracies | Standard deviation distance measurement 10 mm for D ≤ 10 m and (Distance in m x 0.001) for D > 10 m |
Range | 2 –100 m (electronic) |
Time for single measurement | <3 sec |
Compensator | Magnet damped pendulum compensator (range +/- 10 min) |
Telescope | Magnification (optical) 24x |
Environmental conditions | IP55 |
Power supply | AA dry cells (4 x LR6/AA/AM3 1.5 V) |
Weight | <2.5 kg |
Product Details:
Usage/Application | Construction |
Model Name/Number | Sprinter 150M |
Level Accuracy | 1.5 mm |
Warranty | 1 year |
Brand | Leica |
Range | 2 to 100 m (electronic) |
Technical Data | Sprinter 150 / 150 M |
Telescope | Magnification (optical) 24x |
Height accuracies Electronic measurement Optical measurement | Standard deviation height measurement per 1 km double run (ISO 17123-2) |
1.5 mm | |
With standard aluminum E-scale/Numeral staff: 2.5 mm | |
Single staff reading | Standard Deviation: 0.6 mm (electronic) and 1.2 mm (optical) at 30 m |
Distance accuracies | Standard deviation distance measurement 10 mm for D ≤ 10 m and (Distance in m x 0.001) for D > 10 m |
Time for single measurement | <3 sec |
Compensator | Magnet damped pendulum compensator (range +/- 10 min) |
Product Details:
Usage/Application | Construction |
Model Name/Number | Sprinter 250M |
Level Accuracy | 1 mm |
Warranty | 1 year |
Brand | Leica |
Technical Data | Sprinter 150 by 150 M |
Range | 2 to 100 m electronic |
Telescope | Magnification (optical) 24x |
Specifications:
Height accuracies Electronic measurement Optical measurement | Standard deviation height measurement per 1 km double run (ISO 17123-2) |
1.0/0.7* mm | |
With standard aluminum E-scale/Numeral staff: 2.5 mm | |
Single staff reading | Standard Deviation: 0.6 mm (electronic) and 1.2 mm (optical) at 30 m |
Distance accuracies | Standard deviation distance measurement 10 mm for D ≤ 10 m and (Distance in m x 0.001) for D > 10 m |
Time for single measurement | <3 sec |
Compensator | Magnet damped pendulum compensator (range +/- 10 min) |
Product Details:
Optical Measurement | From 0.6 m |
Storage Temperature | 40Degree C to +70Degree C |
Working Temperature | 20Degree C to +50Degree C |
Dust Water | IP53 |
Humidity | 95%, Non Condensing |
Electronic Measurement | 1.8 m to 110 m |
Technical data | LEICA DNA03 | LEICA DNA10 |
Area of use | Quick measurements of heights, Height differences and stake outs | Quick measurements of heights, Height differences and stake outs |
I. and II. order levelling | Cadastral levelling | |
High precision measurements | Precision measurements | |
Accuracy | Standard deviation height measurement per 1km | |
Double-run (ISO 17123-2) | ||
Electronic measurements: | ||
With Invar staffs | 0.3mm | 0.9mm |
With standard staffs | 1.0mm | 1.5mm |
Optical measurements | 2.0mm | 2.0mm |
Distance measurement (standard deviation) | (electr.) 1 cm/20 m (500 ppm) |